Shunt resistors

A shunt (aka a current shunt resistor or an ammeter shunt) is a high precision resistor which can be used to measure the current flowing through a circuit. Using Ohm's Law we know that the voltage dropped across a resistor divided by the resistance of that resistor is equal to the current, therefore if we measure the voltage across a shunt resistor in a circuit, we can easily calculate the current.

100 Amp Current Shunt Resistor

For example, pictured above is a typical 100 Amp Shunt Resistor. This can be used to measure currents of up to 100 Amps - although to prevent overheating it should really only be used to measure continuous currents of no more than 60-70 Amps.
* If a shunt resistor overheats it can permanently change the resistance of the shunt.

This shunt is calibrated such that the voltage drop across it is 100mV when the current flowing through it is 100 Amps. Therefore we can calculate the resistance of this shunt to be voltage divided by current = 0.1 / 100 = 0.001 Ohms (typically to within ± 0.25% accuracy). Therefore if a voltage drop of 28mV is measured (using a standard multimeter or 0-100mV range voltmeter), we know that the current flowing is 0.028/0.001 = 28 Amps.
(The power wasted by the shunt resistor is given by multiplying the voltage by the current = 0.028 * 28 = 0.78 Watts in this example.)

To save making this calculation manually each time it is possible to re-label a 0-100mV moving coil voltmeter so it instead reads 0-100 Amps. This would be achieved simply by sticking the word "Amps" over "mV" on the face of the meter which would now be an ammeter rather than a voltmeter.

0-30A Ammeter with Shunt resistor

Using a Shunt Resistor in a Renewable Energy System

It is very important to know how much current is flowing in and out of the battery bank in a renewable energy system. When charging the current flowing into the batteries should never be more than 10% of the battery capacity - e.g. a 100Ah battery should not be charged with more than a 10 Amp current or it may be damaged and/or overheat.

It is also very useful to know how much current is being generated by a wind turbine or solar panel, because that information helps you to calculate how much power is being generated. For example a 12 Volt 15 Watt PV Solar Panel may produce a voltage of 18 Volts when it is very cloudy and 21 Volts when it is very sunny.
When it is cloudy you may measure a current of just 0.1 Amps and when it is sunny a current of 0.8 Amps. Power is equal to voltage multiplied by current, so the solar panel is generating just 2 Watts when it is cloudy and almost 17 Watts when it is sunny.

Make Your Own Shunt Resistors

It is possible to Make a Basic Shunt Resistor very cheaply with some copper wire. Click here to find out more.
Article Last Modified: 12:52, 28th Feb 2007

Comment on this Article

If you have any comments on this article, please email them to neil@reuk.co.uk.


Recommended Related Articles

People who read this article also enjoyed the following articles:

Make a Shunt Resistor
Make your own rough and ready shunt resistor
Article Last Modified: 12:52, 28th Feb 2007
electric circuit | education

Basic Ammeters and Voltmeters
Find out how to monitor the health of your RE system's generator and batteries
Article Last Modified: 18:17, 26th Feb 2007
electronics | storage | wind | solar

Ohms Law
Learn about Ohm's Law and how it is used in Renewable Energy systems
Article Last Modified: 12:15, 23rd Feb 2007
electric circuit | education

Make a Simple Battery Status Monitor
Monitor battery status with this easy electric circuit project - no skill required!
Article Last Modified: 12:33, 16th Mar 2007
storage | electric circuit

Three Phase Basics
Get an understanding of three phase wiring in wind turbine alternators
Article Last Modified: 15:13, 19th Aug 2008
wind | electric circuit | websites

AWG to Square mm Wire Size Converter
Convert between AWG, inches and mm diameter, and square mm area measures of wire size
Article Last Modified: 06:45, 19th Jul 2008
storage | electric circuit

200W 12V Immersion Heater
Using a wind turbine to heat water for your home via an immersion heater element
Article Last Modified: 13:21, 4th Sep 2008
heating | wind | water

Power Inverters
Find out about the uses of power inverters in renewable energy generation
Article Last Modified: 16:41, 21st Jul 2008
storage | general | electronics

What is a Zener Diode
Find out more about the Zener diode
Article Last Modified: 10:20, 10th Feb 2009
electric circuit | education

Interconnecting Batteries for Battery Bank
Find out how best to connect batteries together into a battery bank
Article Last Modified: 13:53, 23rd Feb 2007
storage

© 2006-2009 REUK - All Rights Reserved
Page Last Updated on 6th November 2009 at 01:36:09pm

Latest
Articles


Drying Clothes Indoors
Tips on drying clothes indoors without a tumble drier
energy efficiency
15:57, 29th Oct 2009

Google Powermeter
Google Powermeter - an online tool to track your home or office electricity consumption in real time online
energy efficiency
13:23, 29th Oct 2009

UK Renewable Energy Degree Courses
Study renewable energy at university in the UK
education
11:18, 29th Oct 2009

Solar Charge Controller
Find out more about Solar Charge Controllers
solar
11:12, 29th Oct 2009

Storing Wind Power with Compressed Air
Find out how wind power can be stored and sold at times of peak demand
wind
07:51, 9th Oct 2009

Simple Solar Water Preheating System
Use solar power to pre-heat water and reduce electricity/gas consumption
solar
14:47, 7th Oct 2009

Battery Desulfation
Find out how to desulfate/desulphate and rejuvenate lead acid batteries
storage
16:56, 5th Oct 2009

Drayton SHR52120 Solar Thermal Controller
Find out more about (and buy) the Drayton SHR 521 20 solar thermal controller
solar
11:44, 3rd Oct 2009



REUK Shop

Popular Items


REUK SUPER TIMER
User programmable 12V powered 10A rated repeating relay timer. 1 second to 99 hours ON and OFF times
£19.99 each.
Complete Circuits



SOLAR PUMP CONTROLLER WITH RELAY
Solar water heating system microprocessor controlled circuit with fitted 10A relay
£25.99 each.
Complete Circuits



12 VOLT 5 WATT SOLAR PANEL
Waterproof 12 Volt 5 Watt Solar Panel with aluminium frame - 290mm x 205mm x 17mm with fitted 5m leads
£33.99 each.
Solar Power



300 WATT POWER INVERTER
Convert 12V DC battery power into 230 AC to power portable televisions, computers, video recorders etc. 300 Watt power rating - peak power 600 Watts
£29.99 each.
Renewable Energy System Parts



CONVERTED PROGRAMMABLE DIGITAL TIMER RELAY
Mains powered programmable timer converted to low voltage with relay board
£21.99 each.
Renewable Energy System Parts



12 VOLT REGULATOR
Supply a fixed 12.0 Volt DC to your devices (up to 1 Amp output)
£4.99 each.
Complete Circuits



MR16 CERAMIC BULB HOLDER
Bulb holder for 12 Volt LED spotlight bulbs
£1.39 each.
Energy Efficient Lighting